EasyManuals Logo
Home>Agilent Technologies>Test Equipment>5000 Series

Agilent Technologies 5000 Series User Manual

Agilent Technologies 5000 Series
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
86 5000 Series Oscilloscopes Service Guide
5 Replacing Assemblies
To remove the keyboard assembly
1 Perform the following procedures:
“To remove the cabinet” on page 80
“To remove the front panel assembly” on page 83
2 If removing the softkey pad only skip steps 3, 4c, and 4d
below.
3 Remove all of the knobs by pulling them straight out. You may
need to use a flat-blade screwdriver to gently pry them as you
pull.
Using a twisting motion rather than prying prevents marking
or damaging the front panel.
4 Remove the main keyboard and softkey board as follows.
a Lift the left end of the softkey board enough to clear the
tab holding it in place.
b Slide the softkey board to the left to release it from the
retaining tabs.
c Release the 8 latches holding the main keypad board to the
front panel.
d You will notice the latches do not all face the same
direction. This is shown with arrows in the following
figure.
e Lift the board up just enough to clear the latches.
f Lift both boards out being careful not to damage the
ribbon cable between them.
5 Remove and replace keypads as needed.

Table of Contents

Other manuals for Agilent Technologies 5000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 5000 Series and is the answer not in the manual?

Agilent Technologies 5000 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model5000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals