218 Rockwell Automation Publication 1783-UM007G-EN-P - February 2017
Chapter 7 Configure Switch Features
Figure 14 shows an example of a switch configured for redundant gateway. All
ports are assigned to VLAN 1.
Figure 14 - Redundant Gateway Switch Ports
When the switch acts as the active redundant gateway, traffic on the switch
that is assigned to VLAN 1 can flow between ports A, B, C, D, and E.
When the switch acts a backup redundant gateway, traffic on the switch that is
assigned to VLAN 1 can flow as follows:
Between only Ports A and B
Between only Ports C, D, and E
To join the ring, traffic on Ports C, D, and E must flow through the non-
DLR port, through devices connected to the backup redundant gateway,
and then through the active redundant gateway (see
Figure 15).
If the backup gateway subsequently becomes the active gateway, traffic
then begins to flow between all ports.
Port Configuration
A DLR access port
B DLR access port
C Redundant gateway uplink port
D Redundant gateway uplink port
E Non-DLR port
IMPORTANT Traffic flow restrictions from the backup gateway to the ring include
CIP and Device Manager traffic. As a result, all traffic flowing from a
ring device to the backup gateway must use this path:
Exit the ring through the active gateway
Flow through the outside network above the ring
Enter the backup gateway through the uplink port.
C
AB
D
E

Table of Contents

Other manuals for Allen-Bradley Stratix 5700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Stratix 5700 and is the answer not in the manual?

Allen-Bradley Stratix 5700 Specifications

General IconGeneral
ModelStratix 5700
Port TypesRJ45, SFP
MountingDIN Rail or Panel Mount
DimensionsVaries by model
WeightVaries by model
ManagementWeb-based, SNMP, Command Line
RedundancyDevice Level Ring, STP, RSTP
Operating Temperature-40°C to 70°C
Power SupplyDual DC inputs
Input Voltage24 VDC or 100-240 VAC
ProtocolsEtherNet/IP, DLR
Security FeaturesSSH, HTTPS, RADIUS, TACACS+

Related product manuals