Error Codes
Following is a list of possible error codes for an electronic con-
trol.Errors beginning with Ei refer to external device Infra-red
communication errors. Errors beginning with EC refer to card
reader errors. All other errors refer to machine errors.
NOTE: Fatal Errors will show oUt oF ordEr along with
the error on the display. If enabled, press the Normal
and Permanent Press keypads to clear fatal errors.
Display Description Cause/Corrective Action
Ei01
Transmission Failure Communication failure. Re-aim external device and try again.
Ei02
Time-out Error Communication failure. Re-aim external device and try again.
Ei03
Invalid Command Code Communication successful, but the command was not valid for this
machine type, or the control could not perform the command in its
current mode of operation. Ensure data is for current machine type
and control is in correct mode.
Ei04
Expecting Upload Request Communication failure. Re-aim external device and try again.
Ei05
Invalid or Out-of-Range Data The value in at least one of the programming options is invalid or
out of range. Recheck the programming option’s value and try
again.
Ei09
CRC-16 Error Communication failure. Re-aim external device and try again.
Ei0A
Framing Error Communication error. Re-aim external device and try again.
Ei0C
Time-out Exceeded Communication error. Re-aim external device and try again.
Ei0E
Encryption Error Communication error. Re-aim external device and try again. If the
problem persists, check that the security code is correct.
Ei0F
Infra-red Disabled Communication failure or infra-red is disabled. Manually enable in-
fra-red on control or re-aim external device and try again.
EC02
Time-out Error Communication failure. Try card again.
EC03
Invalid Command Code Communication successful, but the command was not valid for this
machine type, or the control could not perform the command in its
current mode of operation. Ensure data is for current machine type
and control is in correct mode.
EC05
Invalid or Out-of-Range Data The value in at least one of the programming options is invalid or
out of range. Recheck the programming option’s value and try
again.
EC11
No Card Reader Initialization Communication is valid, but there is no card reader initialization.
Power down, power up and try again.
EC18
No Communication Card reader is initialized, communication lost. Power down, power
up and try again. If error persists, replace control or card reader.
EC19
No Card Reader Communication Communication failure. Power down, power up and try again. If er-
ror persists, replace control or card reader.
Table 37  continues...