Display Description Cause/Corrective Action
E StHt
Slow To Heat Error (Heat Models
Only)
Non-Fatal Error that will appear during the running cycle without
affecting the cycle.
The control sounds an alarm tone for 15 seconds.
To clear the error, press any keypad.
E SudS
Suds Lock Error In the spin steps, if the control determines that there are suds in the
machine after running all programmed Suds Routines, it will dis-
play a Suds Lock Error at the end of the cycle after the door is
opened.
To clear the error, wait 1 minute, open the door, or press any key-
pad.
Eio 29
Mosfet Enable Pin Failure The Input/Output Board senses a problem with the hardware.
The control sounds an alarm tone for 15 seconds.
To clear this error either power down the machine or simultaneous-
ly press the Normal and Warm keypads.
Eio 30
Door Lock Solenoid Disable Pin
Failure
The Input/Output Board senses a problem with the hardware.
The control sounds an alarm tone for 15 seconds.
To clear this error either power down the machine or simultaneous-
ly press the Normal and Warm keypads.
Eio 31
Door Lock Solenoid Pulse Pin Fail-
ure
The Input/Output Board senses a problem with the hardware.
The control sounds an alarm tone for 15 seconds.
To clear this error either power down the machine or simultaneous-
ly press the Normal and Warm keypads.
Eio 32
Door Lock Solenoid Relay Pin Fail-
ure
The Input/Output Board senses a problem with the hardware.
The control sounds an alarm tone for 15 seconds.
To clear this error either power down the machine or simultaneous-
ly press the Normal and Warm keypads.
Eio 33
Mosfet Enable Hardware Failure The Input/Output Board senses a problem with the hardware.
The control sounds an alarm tone for 15 seconds.
To clear this error either power down the machine or simultaneous-
ly press the Normal and Warm keypads.
Eio 34
Door Lock Solenoid Disable Hard-
ware Failure
The Input/Output Board senses a problem with the hardware.
The control sounds an alarm tone for 15 seconds.
To clear this error either power down the machine or simultaneous-
ly press the Normal and Warm keypads.