Errors Menu Error-
E oP
Open Thermistor Sensor Error Display (Heat
Models) (On/Off) - If the control senses an
open thermistor at anytime during a cycle, the
control will not attempt to heat nor regulated
the fill temperature using valves. If the error
display is enabled the Error Display is shown
at end of cycle until the door is opened or a
keypad is pressed.
E SH
Shortened Thermistor Sensor Error Display
(Heat Models) (On/Off) - If the control
senses a shorted thermistor at anytime during
a cycle, the control will not attempt to heat
nor regulated the fill temperature using
valves. If the error display is enabled the Er-
ror Display is shown at end of cycle until the
door is opened or a keypad is pressed.
EStH
Slow to Heat Error (Heat Models) - The error
will display if the water temperature has not
changed 5°F[3.75°C] from the start of heat-
ing within the programmed time (if greater
than 0 minutes). This error will not stop the
heater from heating, and any keypad can be
pressed to clear the error display.
E Ht-
Heat Error Display (Heat Models)
E Ht1
Heat Error (On/Off) - If enabled,
the control will set error after
heater error alarm time if target
water temperature isn't reached, if
disabled will allow heating forev-
er until target temperature is
reached. Shown at end of cycle
until the door is opened or a key-
pad is pressed.
E Ht2
Heat Error Time - Time allowed
in minutes to reach target water
temperature before setting the
heater error.
E Ub
Non-Fatal Unbalance Error - Error shown at
end of cycle if a programmed spin speed was
not reached due to an unbalanced load.
Shown after the door is opened or a key is
pressed. This error will remain displayed un-
til another keypad has been pressed or one
minute passes.
Table 6  continues...
Errors Menu Error-
E SL
Suds Lock Error Display - Shown at end of
cycle after the door is opened or a keypad is
pressed if suds were still detected in the ma-
chine after all Suds Removal Routines al-
lowed have been run in the cycle. Will be
cleared after one minute or if a keypad is
pressed.
SUd-
Suds Removal Routine Menu
SUd 1
Suds Removal Routine Display
(On/Off) - Will show SUdS on
the display while a Suds Removal
Routine is being performed dur-
ing the cycle.
SUd 2
Suds Removal Routines Allowed
Per Cycle - Allows the owner to
pick how many Suds Removal
Routines are allowed per cycle.
SUd 3
Suds Removal Routine Extra
Time (On/Off) - If programmed to
On, the Suds Removal Routines
will pause cycle time to perform
suds removal routines, if Off, the
Suds Removal Routines will use
cycle time which may result in
poorer machine performance.
ovrFLd
Overflow Mode Display - Can be used to dis-
able oFLd on the display while in an Over-
flow Condition during a running cycle if set
to Off. In all other modes, it will always
show oFLo if an overflow condition exists.
CLrErr
Allow Error Clearing (On/Off) - Allows the
ability for the owner to clear most errors by
pressing Normal and Permanent Press key-
pads. Some errors will still require power to
be cycled to clear the error and some errors
will continually set themselves until the con-
dition for the error being set is fixed. Call for
service if an error will not clear.