Programming the Supply Step Type
The Supply Step Type allows the owner to program the addition
of chemicals to the load. After selecting the desired Cycle Step
number and pressing START (enter), XXSUPP will appear in the
display. Press the Delicates Bulky () or the Cold () keypad to
scroll through the options and START (enter) to select a value.
NOTE: To go back to the current programmable option
without changing the value of the active digit, press the
Warm (<) keypad.
Step
Type
Display
A Display B Values Description
XXSUPP Supply Step Type (XX is step number, step type is flash-
ing)
En diS XXSU01 EnAbLe/diSAbL/dNod 1/
dNod 2
Step Enable/Disable
Choosing dNod 1 and dNod 2 will enable the step if
the cycle modifier is chosen and set to be enabled in
Cycle Modifier Programming Menu CNP-.
StAtUS XXSU02 PrEWSH/WASH/rinSE1/
rinSE2/rinSE3/rinSE4/
SPin
Status LED: The corresponding LED on the control will
be lit during this step.
NinUtE XXSU03
0-255 Step Minutes: If Programmed Cycle Time Display is
enabled and set to a value greater than zero, it will over-
ride this time.
SECond XXSU04
0-59 Step Seconds: If Programmed Cycle Time Display is
enabled and set to a value greater than zero, it will over-
ride this time.
v tENP XXSU05 CoLd/WArN/Hot
Water Valve Temperature: This parameter is only used
when an Independent Supply Step. Cold (cold valve),
Warm (cold and warm valves), Hot (hot valves)
dELAy XXSU06
0-255 Delay time allows water to start flowing before chemi-
cals (internal or external) are introduced to the machine.
SHUtoF XXSU07 tiNE/LEvEL
Shutoff for external supplies. It can be set for the pro-
grammed Supply Time or when the last target water lev-
el has been reached.
FiLL XXSU10 on/oFF
Fill Valves (if so equipped)
Fi tUb XXSU11 on/oFF
Tub Fill Valves (if so equipped)
SPrAY XXSU12 on/oFF
Spray Valves (if so equipped)
C HArd XXSU13 on/oFF
Cold Hard Fill Valve (if so equipped)
AUX FL XXSU14 on/oFF
Auxiliary Fill Valve (if so equipped)
CoMP 1 XXSU15 on/oFF
Compartment 1
CoMP 2 XXSU16 on/oFF
Compartment 2
CoMP 3 XXSU17 on/oFF
Compartment 3
CoMP 4 XXSU18 on/oFF
Compartment 4