Chapter 5: Powering On the Switch
117
3. Do one of the following:
If the values in the Nominal Power and Power Allocated fields are
the same, no further installation steps are required. Refer to the
Software Reference for the IE340 Switches for management
instructions.
If the values are different, continue with the next step:
4. Enter the CONFIGURE TERMINAL command to move to the Global
Configuration mode:
awplus# configure terminal
awplus(config)#
5. In the Global Configuration mode. enter the POWER INLINE
WATTAGE MAX command to change the nominal value to be either
equal to or less than the actual wattage value. The format of the
command is given here:
power inline wattage max
max
The max variable is the value from the Power Allocated field from the
SHOW POWER-INLINE command. For example, if the Power
Allocated field has the value 180W, the command would be:
awplus(config)# power inline wattage max 180
The provisioned PoE budget of the switch is now set. Refer to the
Software Reference for the IE340 Switches for management
instructions.

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals