Environmental Specifications
Warning
You must use a UL Listed 3X or 4X enclosure when installing the
device in an outdoor environment.
Table 16. Operating Temperature Ratings
Model Name
Operating Temperature Ranges
1
Rating
Enclosure Type
Sealed
Enclosure:
0 lfm
Ventilated
Airflow:
240 lfm
Cooling Fan
Airflow:
2150 lfm
IE340-12GP
-40°C to 75°C
(-40° F to 167° F)
-40°C to 65°C
(-40° F to 149° F)
-40°C to 70°C
(-40°F to 158°F)
-40°C to 75°C
(-40°F to 167°F)
IE340-12GT
-40°C to 75°C
(-40°F to 167°F)
IE340-20GP
-40°C to 65°C
(-40° F to 149° F)
-40°C to 70°C
(-40°F to 158°F)
-40°C to 75°C
(-40°F to 167°F)
IE340L-18GP -40°C to 65°C
(-40° F to 149° F)
-40°C to 55°C
(-40°F to 131°F)
-40°C to 65°C
(-40°F to 149°F)
1. These values are for vertical mounting orientation. For horizontal mounting orientation, reduce the
maximum values by 5
°C.
Table 17. Environmental Specifications
Storage Temperature -40° C to 85° C (-40° F to 185° F)
Operating Humidity 5% to 95% noncondensing
Storage Humidity 5% to 95% noncondensing
Maximum Operating Altitude 3,000 m (9,843 ft)
Table 18. Ingress Protection
IE340 Switch IP30

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals