LW500A/LW600A PULSED Nd:YAG LASER
x 990-539
WARNING
Wear protective glasses.
Be sure to wear protective glasses while using the laser. Even with eye protection, you may
lose your sight if you look directly at the laser beam.
Do not expose your skin to the laser beam.
Your skin may be severely burned.
Do not touch any processed part during, or immediately after processing.
Welded parts are very hot.
Use only specified cables.
A cable with insufficient capacity or loose connections can cause electric shock or fire.
Do not use a damaged power cable, connecting cables, or plugs.
Do not step on, twist, or tense any power cable. The power cable and connecting cables
may be damaged which can cause electric shock, short circuit, or fire. If any part needs to be
repaired or replaced, consult Amada Miyachi America or your distributor.
Stop operation if any trouble occurs.
If you detect a burning smell, abnormal sounds, abnormal heat, smoke, etc. from the Laser,
turn the power OFF immediately to prevent fire or electric shock. Contact Amada Miyachi
America or your distributor for help.
Ground the Laser.
If the Laser is not grounded, you may get an electric shock when there is trouble or if
electricity leaks through the protective insulation.
Use a stopper plug.
Laser beams are dangerous to the human body. Prevent accidental leakage of the laser
beam by using a stopper (a heat-resistant, laser beam absorbing material).
People with pacemakers
MUST
stay away from the Laser.
When the Laser is operating, it generates a magnetic field, which adversely affects
pacemakers. People who use a pacemaker must not approach the Laser, or walk around
the laser shop while the Laser is operating, unless their medical doctor has deemed it safe to
do so.