101
Rammax 1515-M/-MC/-MI/-MCI
Index: a; Issued 08/2010
Error
code:
Meaning: Cause: Solution:
Err 13 Tilt sensor triggered Machine is tilted. Set the machine erect
Control unit in wrong
position
Example: Installation
position wrong / installed
wrong after repair, or not
secured for the test.
Check the control for
placement and position
and correct, if necessary.
Err 21 Proximity switch stays
on. This error can only
occur during active in-
frared control.
Operator is standing too
close to the machine.
Increase the distance
between the transmit-
ter (operator) and the
machine.
Err 23 No RPM signal. Regulator error (broken
cable, chang point)
Replace regulator. Re-
place cable.
This error message also
occurs during engine
shut-down.
When the engine goes
off, the controls query the
status of the alternator.
No error / belongs to
shut-off program.
appendix