Variable excentric weight option
Machines with variable excentric weight use two different
compression parameters. This option enables you to optimise
the machine for use on different surfaces. The compression
parameter selector switch is tted on the left, above the cock-
pit:
Fig. 1OV1 Selector switch location
Fig. 2OV2 Selector switch
Compression parameter selector switch
The selector switch has two positions:
Switch position 1: Activates the larger amplitude. Use this
switch position when working on saturated ground.
Switch position 2: Activates the smaller amplitude. Use this
switch position when working on grainy and sandy ground or
on gravel.
You can switch between the compression parameters at any
time, even when you are using the vibration function.
controls