71
Rammax 1515-M/-MC/-MI/-MCI
Index: a; Issued 08/2010
Fig. MB6: Machine at the bottom of an embankment Fig. MB7: Vibration reverse
Changing the control mode
It might become necessary to change to another control mode
whilst working. This can be done at any time. Bear the fol-
lowing in mind:
The machine only reacts to the control mode with which
your engine was started.
You can change over directly from remote infrared or cable
control to manual control.
You must use the active remote control to switch the engine
off rst if you want to change beteen the two remote control
modes.
Shutting down / parking the machine
Bear the following points in mind when shutting the machine
down:
Always try to park the machine on a level surface.
Always use chocks if the machine if the machine has to
be parked on a slope.
You must ensure that the machine is not in anybody
else's way.
Retract the shut down yoke.
Always remove the ignition key from the ignition lock.
Stow the remote controllers in their correct places.
Close the covers and aps.
Drive the machine on level ground.
Turn the ignition key back to position 1 and remove it.