92
Rammax 1515-M/-MC/-MI/-MCI
Index: a; Issued 08/2010
Servicing the battery
The battery is maintenance-free as per EN/DIN. That means
it that during normal operating temperatures and correct con-
troller voltage no water must be relled. Water is used up
in the case of deviation from the standard conditions. The
following among others is considered as a deviation from nor-
mal conditions:
High outside temperatures
Demanding machine use
Continuous operation on upward and downward gradien-
ts at extreme end of the range (just below the maximum
gradeability).
The battery is located under the engine protector, on the left
alongside the diesel engine (Fig. MW12).
Fig. MW12 Battery position
It is advisable to check the water level of the battery in regular
intervals. The service life is reduced substantially, if the batte-
ry is operated with a too low water level.
Clean the battery terminals and cable clips regularly and then
grease generously using acid-resistant grease.
•
•
•
Maintaining the Machine