48
Rammax 1515-M/-MC/-MI/-MCI
Index: a; Issued 08/2010
Cockpit view
888888
1 2 43
1 Ignition lock
2
Remote cable controller connection socket (not
tted with Rammax 1515-M)
3 Warning lights
4 Display
Warning lights
Load check warning light
This warning light illuminates when the alternator is not ge-
nerating the voltage. The stop program will be activated after
the warning light has been on for 4 seconds. The machine is
shutdown.
Possible cause: The alternator is defective. Contact your
service workshop.
Oil pressure warning light
This warning light illuminates when the engine oil pressure
drops. The stop program will be activated after the warning
light has been on for 4 seconds. The machine is shutdown.
It can only be moved again after the cause of the emergency
stop has been eliminated.
Possible cause: Normally it is caused by the engine lling
level being too low and it must be relled with engine oil
See Page 63, "Refilling with engine oil“ section. Contact your
service workshop if low engine oil is not the casue.