NOTE
Diesel engine run-on!
Despite activation of the stop signal, the diesel engine may run
on for a while. This happens in the following situations:
If the diesel engine is started and switched off several
times during a short period.
When there is air in the fuel circuit.
After start-up, let the diesel engine run for at least 5 minutes.
Avoid short running times and intervals.
Don’t run the fuel reserve all the way to empty. Fill the fuel
tank in a timely manner.