Chapter 7 Remote Commands
7-78
:SENSe:MEASure:EDIagram:ELAPsed?
Response <day>=<NR1 NUMERIC RESPONSE DATA>
0, 1 to 99 0 to 99 days
<hour>=<NR1 NUMERIC RESPONSE DATA>
0 to 23 0 to 23 hours
<minute> = <NR1 NUMERIC RESPONSE DATA>
0 to 59 0 to 59 minutes
<second> = <NR1 NUMERIC RESPONSE DATA>
0 to 59 0 to 59 seconds
Note:
The following is output when no measurement is performed:
0,0,0,0
Function Queries the Eye Diagram measurement elapsed time (Elapsed Time).
Example > :SENSe:MEASure:EDIagram:ELAPsed?
< 99,23,59,59
Compatibility Incompatible with existing models.
:CALCulate:DATA:EDIagram:STATus?
Response <string>=<STRING RESPONSE DATA>
" " When no alarm exists
"Sync Loss" Sync Loss
"Clock Loss" Clock Loss
"Out of range" Out of range
"Illegal Error" Illegal Error
"Meas. Threshold exceeded" Number of errors exceeds the target rate
Note:
If two or more alarms have occurred, the one with the highest
priority is returned:
Illegal Error > Clock Loss > Sync Loss > Out or range
Function Queries the status condition during Eye Diagram measurement.
Example > :CALCulate:DATA:EDIagram:STATus?
< "Sync Loss"
Compatibility Incompatible with existing models.