4.3 Displaying Measurement Results
4-9
4
Window Operations
Table 4.3.2-1 Configuration of Measurement Result Display window
Item Function
[1]
ER
Displays the total error rate of MU183040A/B Slot4 Data1-2.
EC
Displays the total error count of MU183040A/B Slot4 Data1-2.
%EFI
Displays the total %EFI (Error Free Interval) of MU183040A/B
Slot4 Data1-2.
EI
Displays the total EI (Error Interval) of MU183040A/B Slot4
Data1-2.
[2]
Frequency
Displays the total frequency of MU183040A/B Slot4 Data1-2.
Clock Count
Displays the total clock count of MU183040A/B Slot4 Data1-2.
[3]
Clock Alarm
Displays the number of clock alarm intervals of MU183040A/B
Slot4 Data1-2. Also displays alarms using indicators.
Red: Current data
Yellow: History data
Sync Loss
Displays the number of sync loss intervals in MU183040A/B Slot4
Data1-2. Also displays alarms using indicators.
Red: Current data
Yellow: History data
Error
Displays the error status of MU183040A/B Slot4 Data1-2.
Red: Current data
Yellow: History data