EasyManua.ls Logo

Artesyn iHP - Table 1-1; Table 1-2; Table 1-3; Table 1-4

Artesyn iHP
202 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iHP Manual 13 | P a g e
iHP Owners Manual
Table 1-3
OUTPUT General Specifications
Parameter
MODULE CODE
SL
SQ
SW
S8
S1
SA
S2
# Outputs
1
1
1
1
1
1
1
Nominal O/P (V)
12.0 V
24.0 V
48.0 V
80.0 V
125.0 V
200.0V
250.0 V
Max Power (W)
2400 W
2880 W
3000 W
3000 W
3000 W
3000 W
3000 W
O/P Current
Range (A)
0.0 A - 200 A
0.0 A - 120 A
0.0 A - 62.5 A
0.0 A - 37.5 A
0.0 A -24 A
0.0 A -15 A
0.0 A -12 A
Power Density
(W/cu-in)
32.5
39.0
40.6
40.6
40.6
40.6
40.6
Efficiency (%)
93.5
93.5
93.5
93.5
93.5
93.5
93.5
Module Input
Voltage
400 V
Module
Operating Temp
-0 °C to +65 °C; Baseplate Temp TBD
Series Operation
12V, 24V & 48V modules can be connected in series up to 300 V for Medical
12V, 24V & 48V modules can be connected in series up to 400 V for ITE
80V, 125V, 200V & 250 V modules can be connected in series up to 800 V for Medical
80V, 125V, 200V & 250 V modules can be connected in series up to 1000 V for ITE
Parallel
Operation
Up to 8 modules can be paralleled in 1 rack, with up to 6 racks connected in parallel. Single Wire Parallel
connection will be provided as part of configuration

Table of Contents