iHP Manual 29 | P a g e
iHP Owners Manual
Figure 2-9 Output modules in series and parallel
Please see Table 2-4 as a guide for what modules can be connected in series and combined voltage limitation
per safety isolation compliance.
Table 2-4
Model Number
Model
Code
Module Nominal
Voltage
Safety Compliance
Maximum Total
Voltage Allowed
73-936-0012
73-936-0024
73-936-0048
SL
SQ
SW
≤ 48V
Medical 2MOPP*
Medical 2MOOP**, ITE
300V
400V
73-936-0080
73-936-0125
73-936-0200
73-936-0250
S8
S1
SA
S2
≥ 80V
Medical 2MOPP
Medical 2MOOP
Medical 2MOOP
ITE
600V
800V
800V
1000V
Note: * - 2MOPP or 2 x MOPP (Means of Patient Protection)
** - 2MOOP or 2 x MOOP (Means of Operator Protection)
2.5.7 Output Blocking Diode and Antiparallel Diode Recommendation