EasyManua.ls Logo

Artesyn iHP - B.4 Data Format: Linear

Artesyn iHP
202 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iHP Manual 172 | P a g e
iHP Owners Manual
Command
Command Name
Transaction
Type
# of
Bytes
Data
Format
Multiplie
r
Data
Unit
Write
Protection
79h
STATUS_WORD
Read Byte
2
Bitmapped
N/A
N/A
N/A
7Dh
STATUS_TEMPERATUR
E
Read Byte
1
Bitmapped
N/A
N/A
N/A
7Eh
STATUS_CML
Read Byte
1
Bitmapped
N/A
N/A
N/A
80h
STATUS_MFR
Read Byte
2
Bitmapped
N/A
N/A
N/A
81h
STATUS_FAN_1_2
Read Byte
1
Bitmapped
N/A
N/A
N/A
82h
STATUS_FAN_3_4
Read Byte
1
Bitmapped
N/A
N/A
N/A
8Dh
READ_TEMPERATURE_
1
Read Byte
2
Linear
N/A
0
C
N/A
8Fh
READ_TEMPERATURE_
2
Read Byte
2
Linear
N/A
0
C
N/A
90h
READ_FAN1_SPEED
Read Byte
2
Linear
N/A
RPM
N/A
91h
READ_FAN2_SPEED
Read Byte
2
Linear
N/A
RPM
N/A
92h
READ_FAN3_SPEED
Read Byte
2
Linear
N/A
RPM
N/A
93h
READ_FAN4_SPEED
Read Byte
2
Linear
N/A
RPM
N/A
99h
MFR_ID
Block Read
7
ASCII
N/A
N/A
N/A
9Ah
MFR_MODEL
Block Read
12
ASCII
N/A
N/A
N/A
9Bh
MFR_REVISION
Block Read
2
ASCII
N/A
N/A
N/A
9Ch
MFR_LOCATION
Block Read
1
ASCII
N/A
N/A
Factory
Config
9Dh
MFR_DATE
Block Read
2
ASCII
N/A
N/A
Factory
Config
9Eh
MFR_SERIAL
Block Read
13
ASCII
N/A
N/A
Factory
Config
B0h
FRU_DATA
Block Read
256
ASCII
N/A
N/A
Factory
Config
B5h
MODULE_VRISE_TIME
Block Write
3
Bitmapped
N/A
N/A
Basic
B6h
MODULE_IRISE_TIME
Block Write
3
Bitmapped
N/A
N/A
Basic
CAh
READ_VIN1
Read Word
2
Direct
10
V
N/A
CBh
READ_VIN2
Read Word
2
Direct
10
V
N/A
CCh
READ_VIN3
Read Word
2
Direct
10
V
N/A
CDh
READ_IIN1
Read Word
2
Direct
100
A
N/A
CEh
READ_IIN2
Read Word
2
Direct
100
A
N/A
CFh
READ_IIN3
Read Word
2
Direct
100
A
N/A
D3h
MODULE_CONFIG
Write Word
2
Bitmapped
N/A
N/A
Basic
D6h
MODULE_DETECTION
Read Byte
1
Bitmapped
N/A
N/A
Basic
D7h
MODULE_SAVE
Write Byte
1
Bitmapped
N/A
N/A
Basic
E1h
FW_VERSION
Read Byte
8
ASCII
N/A
N/A
N/A
B.4 Data Format: Linear

Table of Contents