iHP Manual 45 | P a g e
iHP Owners Manual
Table 4-1
Command
Parameter
Default Configuration when shipped from Artesyn
User
Configurable
12V Module
24V Module
48V Module
80V Module
125V Module
200V Module
250V Module
Data
Process
Data
Data
Process
Data
Data
Process
Data
Data
Process
Data
Data
Process
Data
Data
Process
Data
Data
Process
Data
01h
MODULE_OPERATION
80h
ON
80h
ON
80h
ON
80h
ON
80h
ON
80h
ON
80h
ON
Yes
24h
VOUT_MAX
023280h
14.4V
046500h
28.8V
08CA00h
57.6V
0EA600h
96V
16E360h
150V
249F00h
240V
2DC6C0h
300V
No
31h
POUT_MAX
1258h
2400W
12D0h
2880W
12EEh
3000W
12EEh
3000W
12EEh
3000W
12EEh
3000W
12EEh
3000W
No
41h
VOUT_OV_FAULT_RESPONSE
80h
*
80h
*
80h
*
80h
*
80h
*
80h
*
80h
*
No
45h
VOUT_UV_FAULT_RESPONSE
80h
*
80h
*
80h
*
80h
*
80h
*
80h
*
80h
*
No
48h
OV_FAULT_LIMIT_MULTIPLIER
2EE0h
120%
2EE0h
120%
2EE0h
120%
2EE0h
120%
2EE0h
120%
2EE0h
120%
2EE0h
120%
Yes
49h
OV_WARN_LIMIT_MULTIPLIER
2904h
105%
2904h
105%
2904h
105%
2904h
105%
2904h
105%
2904h
105%
2904h
105%
Yes
4Bh
UV_FAULT_LIMIT_MULTIPLIER
2134h
85%
2134h
85%
2134h
85%
2134h
85%
2134h
85%
2134h
85%
2134h
85%
Yes
4Ch
UV_WARN_LIMIT_MULTIPLIER
2328h
90%
2328h
90%
2328h
90%
2328h
90%
2328h
90%
2328h
90%
2328h
90%
Yes
4Dh
OC_FAULT_LIMIT_MULTIPLIER
2904h
105%
2904h
105%
2904h
105%
2904h
105%
2904h
105%
2904h
105%
2904h
105%
Yes
4Fh
OT_FAULT1_LIMIT
2EE0h
120
o
C
2EE0h
120
o
C
3A98h
150
o
C
30D4h
125
o
C
2CECh
115
o
C
2EE0h
120
o
C
30D4h
125
o
C
No
50h
OT_FAULT_RESPONSE
B8h
*
B8h
*
B8h
*
B8h
*
B8h
*
B8h
*
B8h
*
No
51h
OT_WARN1_LIMIT
2328h
90
o
C
2710h
100
o
C
30D4h
125
0
C
2710h
100
o
C
25C1h
96.65
o
C
251Ch
95
o
C
251Ch
95
o
C
No
52h
OC_RESPONSE_TYPE
00h
*
00h
*
00h
*
00h
*
00h
*
00h
*
00h
*
Yes
B5h
SET_VOLTAGE_RISE_SETTING
00 00h
*
00 00h
*
00 00h
*
00 00h
*
00 00h
*
00 00h
*
00 00h
*
Yes
B6h
SET_CURRENT_RISE_SETTING
00 00h
*
00 00h
*
00 00h
*
00 00h
*
00 00h
*
00 00h
*
00 00h
*
Yes
B7h
SET_IO_ACTIVE_LEVEL_LOGIC
00 02h
*
00 02h
*
00 02h
*
00 02h
*
00 02h
*
00 02h
*
00 02h
*
Yes
B8h
SET_MODULE_LOAD TYPE
00 02h
*
00 02h
*
00 02h
*
00 02h
*
00 02h
*
00 02h
*
00 02h
*
Yes
BAh
ANALOG_FILTER_ENABLE
03h
*
03h
*
03h
*
03h
*
03h
*
03h
*
03h
*
Yes
D3h
MODULE_CONFIG
00h
DVS
00h
DVS
00h
DVS
00h
DVS
00h
DVS
00h
DVS
00h
DVS
Yes
B1h
VREF
12V
24V
48V
80V
125V
200V
250V
Yes
B2h
IREF
200A
126A
65.625A
39.375A
25.2A
15A
12.6A
Yes
E9h
CALIBRATION_DATE
Factory Calibration Date
Yes
**
OT_FAULT1_RECOV
90
o
C
100
o
C
85
o
C
85
o
C
85
o
C
90
o
C
85
o
C
No
**
OT_WARN1_RECOV
90
o
C
80
o
C
85
o
C
85
o
C
65
o
C
85
o
C
85
o
C
No
**
OT_FAULT3_LIMIT
120
o
C
120
o
C
110
o
C
95
o
C
92
o
C
120
o
C
125
o
C
No
**
OT_FAULT3_RECOV
90
o
C
100
o
C
85
o
C
75
o
C
75
o
C
90
o
C
85
o
C
No
**
OT_WARN3_LIMIT
100
o
C
100
o
C
100
o
C
85
o
C
75
o
C
95
o
C
95
o
C
No
**
OT_WARN3_RECOV
90
o
C
80
o
C
85
o
C
70
o
C
55
o
C
85
o
C
85
o
C
No
**
Brick Wall OVP
15.63V
31.3V
64.5V
110V
162V
250V
315V
No
Note: * Bitmapped data, please refer to Appendix B.2 Module Command.
** No assigned command. Parameter is hardcoded in the module firmware.

Table of Contents