7-15
Event type 71 73 7472
Meaning
Message
Deviation lower limit
DEV-L
Deviation lower limit wait
DEV-L-W
Absolute value deviation
upper limit
A-DEV-H
Deviation upper limit wait
DEV-H-W
Range of auxiliary
setting 1
Message
Hysteresis
0 to 1000 SPU
hysteresis
Hysteresis
0 to 1000 SPU
hysteresis
Hysteresis
0 to 1000 SPU
hysteresis
Hysteresis
0 to 1000 SPU
hysteresis
Range of auxiliary
setting 2
Message
Operating point
-19999 to +20000 SPU
set point
Operating point
-19999 to +20000 SPU
set point
Operating point
0 to 20000 SPU
set point
Operating point
-19999 to +20000 SPU
set point
Setting category
Operation category
Instrument type
PV type
Instrument type
PV type
Instrument type
PV type
Instrument type
PV type
Event type 75 77 7876
Meaning
Message
Absolute value deviation
lower limit A-DEV-L
Absolute value deviation lower limit
with stanby A-DEV-L-W
PV deviation rate upper limit
D-PV-H
Absolute value deviation upper limit
with stanby A-DEV-H-W
Range of auxiliary
setting 1
Message
Hysteresis
0 to 1000 SPU
hysteresis
Hysteresis
0 to 1000 SPU
hysteresis
Sampling cycle
0.1 to 600.0 sec
sampling rate
Hysteresis
0 to 1000 SPU
hysteresis
Range of auxiliary
setting 2
Message
Operating point
0 to 20000 SPU
set point
Operating point
0 to 20000 SPU
set point
Operating point
—19999 to +20000 SPU
set point
Operating point
0 to 20000 SPU
set point
Setting category
Operation category
Instrument type
PV type
Instrument type
PV type
Instrument type
PV type
Instrument type
PV type
Event type 79 81 8280
Meaning
Message
PV deviation rate lower limit
D-PV-L
SP lower limit
SP-L
MV upper limit
MV-H
SP upper limit
SP-H
Range of auxiliary
setting 1
Message
Sampling cycle
0.1 to 600.0sec
sampling rate
Hysteresis
0 to 1000 SPU
hysteresis
Hysteresis
0.0 to 100.0%
hysteresis
Hysteresis
0 to 1000 SPU
hysteresis
Range of auxiliary
setting 2
Message
Operating point
-19999 to +20000 SPU
set point
Operating point
-19999 to +20000 SPU
set point
Operating point
-5.0 to +105.0%
set point
Operating point
-19999 to +20000 SPU
set point
Setting category
Operation category
Instrument type
PV type
Instrument type
PV type
Instrument type
PV type
Instrument type
PV type
Event type 83 85 8684
Meaning
Message
MV lower limit
MV-L
SOAK absolute value deviation
lower limit S-A-DEV-L
SOAK absolute value deviation upper
limit with stanby S-A-DEV-H-W
SOAK absolute value deviation
upper limitt S-A-DEV-H
Range of auxiliary
setting 1
Message
Hysteresis
0.0 to 100.0%
hysteresis
Hysteresis
0 to 1000 SPU
hysteresis
Hysteresis
0 to 1000 SPU
hysteresis
Hysteresis
0 to 1000 SPU
hysteresis
Range of auxiliary
setting 2
Message
Operating point
-5.0 to +105.0%
set point
Operating point
0 to 20000 SPU
set point
Operating point
0 to 20000 SPU
set point
Operating point
0 to 20000 SPU
set point
Setting category
Operation category
Instrument type
PV type
Instrument type
PV type
Instrument type
PV type
Instrument type
PV type
Event type 87 89 9088
Meaning
Message
SOAK absolute value deviation lower
limit with stanby S-A-DEV-L-W
Segment number binary
code SEG-BIN
Program number BCD
code PROG-BCD
Program number binary
code PROG-BIN
Range of auxiliary
setting 1
Message
Hysteresis
0 to 1000 SPU
hysteresis
Number of output points
1 to 7
channels
Number of output points
1 to 8
channels
Number of output points
1 to 7
channels
Range of auxiliary
setting 2
Message
Operating point
0 to 20000 SPU
set point
Unused UnusedUnused
Setting category
Operation category
Instrument type
PV type
Instrument type
Code type
Instrument type
Code type
Instrument type
Code type