Image Acquisition Control AW00089317000
96 Basler ace GigE
7.4 The Frame Start Trigger
The frame start trigger is used to begin frame acquisition. Assuming that the camera is in a "waiting
for frame start trigger" acquisition status, it will begin a frame acquisition each time it receives a
frame start trigger signal.
Note that in order for the camera to be in a "waiting for frame start trigger" acquisition status:
The Acquisition Mode parameter must be set correctly.
A proper Acquisition Start command must be applied to the camera.
A proper acquisition start trigger signal must be applied to the camera (if the Trigger Mode
parameter for the acquisition start trigger is set to on).
For more information about
the Acquisition Mode parameter and about Acquisition Start and Acquisition Stop commands,
see Section 7.1 on page 83 and Section 7.2 on page 87.
the acquisition start trigger, and about the acquisition status, see Section 7.1 on page 83 and
Section 7.3 on page 89.
Referring to the use case diagrams that appear in Section 7.11 on page 148 can help you
understand the explanations of the frame start trigger.