As mentioned above, the active configuration set is stored in the camera’s volatile memory and the
settings are lost, if the camera is reset or if power is switched off. The camera can save most of the
settings from the current active set to a reserved area in the camera’s non-volatile memory. A
configuration set that has been saved in the non-volatile memory is not lost when the camera is
reset or switched off. There are three reserved areas in the camera’s non-volatile memory available
for saving configuration sets. A configuration set saved in a reserved area is commonly referred to
as a "user set".
The three available user sets are called User Set 1, User Set 2, and User Set 3.
When the camera is running, a saved user set can be loaded into the active set. A saved user set
can also be designated as the "startup" set, i.e., the set that will be loaded into the active set
whenever the camera is powered on or reset. Instructions for loading a saved user set into the
active set and for designating which set will be the startup set appear later in the Configuration Sets
section.
Designating a Startup Set
You can designate the default set or one of the user sets as the "startup" set. The designated startup
set will automatically be loaded into the active set whenever the camera starts up at power on or
after a reset. Instructions for designating the startup set appear below.
For more information about auto functions, see Section 10.13 on page 276.
10.19.1 Selecting a Factory Setup as the Default Set
When the camera is delivered, the Standard Factory Setup will be selected as the default set. You
can, however, select any one of the four factory setups to serve as the default set.
1. Set the Default Set Selector to the Standard Factory Setup, High Gain Factory Setup, Auto
Functions Factory Setup or Color Factory Setup.
The values for the luminance lookup table are not saved in the user sets and are
lost when the camera is reset or switched off. If you are using the lookup table
feature, you must reenter the lookup table values after each camera startup or
reset.
To select which factory setup will be the default set: