EasyManuals Logo

Basler GigE SERIES User Manual

Basler GigE SERIES
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #225 background imageLoading...
Page #225 background image
AW00089317000 Standard Features
Basler ace GigE 215
10.4.4 Enabling and Setting Digital Shift
You can enable or disable the digital shift feature by setting the value of the Digital Shift parameter.
When the parameter is
set to zero, digital shift will be disabled.
set to 1, 2, 3, or 4, digital shift will be set to shift by 1, shift by 2, shift by 3, or shift by 4
respectively.
You can set the Digital Shift parameter values from within your application software by using the
Basler pylon API. The following code snippet illustrates using the API to set the parameter values:
// Disable digital shift
Camera.DigitalShift.SetValue( 0 );
// Enable digital shift by 2
Camera.DigitalShift.SetValue( 2 );
You can also use the Basler pylon Viewer application to easily set the parameters.
For more information about the pylon API and the pylon Viewer, see Section 3 on page 45.