AW00089317000 Standard Features
Basler ace GigE 255
10.8.3.2 Configuration
Configuring Sequence Sets and Advance Control
1. Make sure that the sequencer feature is disabled.
2. Set the Sequence Advance Mode parameter to Free Selection.
3. Set the Sequence Set Total Number parameter. The maximum number is 2.
4. Select the sequence set address bit and set the input line that will act as the control source:
a. Bit 0 will be selected by default as the sequence set address bit. Set input line 1 as the
control source for setting bit 0.
5. Use the Sequence Set Index parameter to select a sequence set index number for the
sequence set currently being populated. The available numbers are 0 and 1.
6. Set up your first acquisition scenario (i.e., lighting, object positioning, etc.)
7. Adjust the camera parameters to get the best image quality with this scenario (you are
adjusting the parameters in the active set).
8. Execute the Sequence Set Store command to copy the sequence parameter values currently
in the active set into the selected sequence set. (Any existing parameter values in the
sequence set will be overwritten.)
9. Repeat the above steps for the other sequence set, starting from step 5.
Configuring Sequence Sets and Advance Control Using Basler pylon
You can use the pylon API to set the parameters for populating sequence sets from within your
application software and make settings for their selection when images are acquired.
The following code snippet gives example settings. It illustrates using the API to set the free
selection sequence advance mode with line 1 as the control source for bit 0 of the sequence set
address, set the total number of sequence sets to 2, and populate sequence sets 0 and 1 by storing
the sequence parameter values from the active set in the sequence sets:
// Disable the sequencer feature
Camera.SequenceEnable.SetValue( false );
// Set the Free Selection sequence advance mode
Camera.SequenceAdvanceMode.SetValue(
SequenceAdvanceMode_FreeSelection );
// Set the total number of sequence sets
Camera.SequenceSetTotalNumber.SetValue( 2 );
// Set line 1 as the control source for setting sequence set address
bit 0
To populate sequence sets and to set the source:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Basler GigE SERIES and is the answer not in the manual?

Basler GigE SERIES Specifications

General IconGeneral
InterfaceGigE
Lens MountC-Mount, CS-Mount
SensorCMOS
MountC-mount, CS-mount
Power SupplyPower over Ethernet (PoE)
DimensionsVaries by model
WeightVaries by model
Operating TemperatureVaries by model

Related product manuals