EasyManua.ls Logo

Basler GigE SERIES - 7.9 Overlapping Image Acquisitions - (Rolling Shutter Models)

Basler GigE SERIES
376 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AW00089317000 Image Acquisition Control
Basler ace GigE 121
The pixel values for each line are read out at the end of exposure for the line. Because the readout
time for each line is also tRow, the temporal shift for the end of readout is identical to the temporal
shift for the start of exposure.
For
calculating the ...
Formula Notes
Reset runtime tRow x (AOI Height -1) tRow: see Table 18.
Total Readout Time [ tRow x (AOI Height) ] + C
TRT
µs C
TRT
= Constant for
evaluating total readout
time. See Table 18.
Total runtime Exposure Time Abs Parameter Setting + Total Readout Time -
Table 17: Formulas for Calculating the Runtime and Readout Time (ERS Mode)
Line 1
Line 2
Line 4
Line 3
Line 5
Line 6
Line 8
Line 7
Line 9
Line 10
Line 11
Line N-2
Line N
Line N-1
tRow
Reset Runtime
Total Readout Time
tRow
Total Runtime
= line exposure
= line readout
Frame Start
Triggered
Fig. 62: Rolling Shutter in the ERS Mode