AW00089317000 Standard Features
Basler ace GigE 209
// Select the feature whose factory limits will be removed.
Camera.ParameterSelector.SetValue( ParameterSelector_Framerate );
// Remove the limits for the selected feature.
Camera.RemoveLimits.SetValue( true );
You can also use the Basler pylon Viewer application to easily set the parameters. Note that the
remove parameter limits feature will only be available at the "guru" viewing level.
For more information about the pylon API and the pylon Viewer, see Section 3 on page 45.