Standard Features AW00089317000
252 Basler ace GigE
address of sequence set 0. Accordingly, sequence set 0 is selected. Its parameter values are
loaded into the active set and are used for the image acquisition.
When the next frame start trigger was received, the camera checks the state of input line 1.
Because the state has not changed the parameter values of sequence set 0 are used for the
image acquisition.
When the next frame start trigger was received, the camera checks the state of input line 1.
Because the state has not changed the parameter values of sequence set 0 are used for the
image acquisition.
When the next frame start trigger was received, the camera checks the state of input line 1.
Input line 1 is found to be high. This corresponds to the address of sequence set 1.
Accordingly, sequence set 1 is selected. Its parameter values are loaded into the active set
and are used for the image acquisition.
Note that the state of input line 1 went high well ahead of the frame start trigger.
Note also that the camera briefly exits the "waiting for frame start trigger" status while the input
line changed its state. This happened when input line 1 went high before the frame start trigger
was receceived (see also Figure 102).
When the next frame start trigger was received, the camera checks the state of input line 1.
Input line 1 is found to be low. This corresponds to the address of sequence set 0. Accordingly,
sequence set 0 is selected. Its parameter values are loaded into the active set and are used for
the image acquisition.
When the remaining frame start triggers were received, the camera checks the state of input
line 1. Input line 1 is found to be high. This corresponds to the address of sequence set 1.
Accordingly, sequence set 1 is selected. Its parameter values are loaded into the active set
and are used for the remaining image acquisitions.
When the remaining frame start triggers were received, the camera checks the state of input
line 1. Because the state has not changed and will not for the remaining frame start triggers the
parameter values of sequence set 1 are used for the image acquisitions.
To ensure reliable selection of a sequence set, allow the elapse of at least one
microsecond between setting the states of the input line and the rise of the
frame start trigger signal.
Also, maintain the state of the input line at least for one microsecond after the
frame start trigger signal has risen.
Make sure not to send a frame start trigger while the input line changes its
state. During this period, the camera will not wait for a frame start trigger and
any frame start trigger will be ignored.
Make sure to only send a frame start trigger when the camera is in "waiting for
frame start trigger" status.
For information about possibilities of getting informed about the "waiting for
frame trigger" status, see the Acquisiton Monitoring Tools section.