Index Event Description CID
Event
Code
CID Point ID SIA
Event
Code
String (Email / Codepad Display)
68 RemoteStay2Arm 3456 998 NM A-Link Area$ STAY2 Arm
69 Duress 1121 User 1 - 32 HA User$$$ Duress Alarm
70 CodepadLocked
(AccessDenied)
1461 881 - 884 JA Codepad $$ Locked
71 KeyfobPanic 1120 301 - 332 PA Keyfob $$ Panic
72 CodepadPanic 1120 881 - 884 PA Codepad $$ Panic
73 CodepadMedical 1100 881 - 884 MA Codepad $$ Medical
74 CodepadFire 1110 881 - 884 FA Codepad $$ Fire
75 RFReceiverMissing 1333 821 EM RF Receiver Missing
76 RFReceiverMissingRestore 3333 821 EN RF Receiver Missing Restore
77 RFReceiverJamming 1344 821 XQ RF Receiver Jamming
78 RFReceiverJammingRestore 3344 821 XH RF Receiver Jamming Restore
79 RFReceiverTamper 1341 821 XS RF Receiver Tamper
80 RFReceiverTamperRestore 3341 821 XJ RF Receiver Tamper Restore
81 RFRepeaterMissing 1333 821 EM RF Repeater $$ Missing
82 RFRepeaterMissingRestore 3333 821 EN RF Repeater $$ Missing Restore
83 RFRepeaterTamper 1341 821 XS RF Repeater $$ Tamper
84 RFRepeaterTamperRestore 3341 821 XJ RF Repeater $$ Tamper Restore
85 CodepadMissing 1333 881 - 884 EM Codepad $$ Missing
86 CodepadMissingRestore 3333 881 - 884 EN Codepad $$ Missing Restore
87 CodepadTamper 1341 881 - 884 ES Codepad $$ Tamper
88 CodepadTamperRestore 3341 881 - 884 EJ Codepad $$ Tamper Restore
89 IPModuleMissing 1333 871 - 872 EM IP Module $$ Missing
90 IPModuleMissingRestore 3333 871 - 872 EN IP Module $$ Missing Restore
91 IPModuleTamper 1341 871 - 872 ES IP Module $$ Tamper
92 IPModuleTamperRestore 3341 871 - 872 EJ IP Module $$ Tamper Restore
93 EXOutputMissing 1333 851 - 852 EM Ex. Output $$ Missing
94 EXOutputMissingRestore 3333 851 - 852 EN Ex. Output $$ Missing Restore
95 EXOutputTamper 1341 851 - 852 ES Ex. Output $$ Tamper
96 EXOutputTamperRestore 3341 851 - 852 EJ Ex. Output $$ Tamper Restore
97 PowerFail 1301 891 AT AC Power Fail
98 PowerRestore 3301 891 AR AC Power Restore
Control Panel Communication Information | en 85
Bosch Security Systems, Inc. Installation Guide 2017.10 | 03 | F.01U.298.026

Table of Contents

Other manuals for Bosch Solution 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 2000 and is the answer not in the manual?

Bosch Solution 2000 Specifications

General IconGeneral
Zones8
Expandable ZonesUp to 16
Event Log100 events
Partitions2
Battery BackupYes
Weight2.5kg
Backup Battery12V 7Ah
Arming OptionsStay, Away
CommunicationPSTN (optional IP module)