Index Event Description CID
Event
Code
CID Point ID SIA
Event
Code
String (Email / Codepad Display)
99 LowBattery 1302 891 YT System Low Battery
100 BatteryRestore 3302 891 YR System Battery Restore
101 AuxPowerFail 1312 891 YI AUX Power Fail
102 AuxPowerFailRestore 3312 891 YJ AUX Power Restore
103 PanelTamper 1341 891 ES Panel Tamper
104 PanelTamperRestore 3341 891 EJp Panel Tamper Restore
105 ProgramChange 1306 891 YG Program Change
106 PhoneLineFail 1351 891 LT Phone Line Fail
107 PhoneLineFailRestore 3351 891 LR Phone Line Restore
108 OutputFail 1320 891 YA Warning Device Fail
109 OutputFailRestore 3320 891 YH Warning Device Restore
110 CommFail 1354 891 YC Comm Fail
111 CommRestore 3354 891 YK Comm Restore
112 CommManualTest 1601 000 RX Comm Manual Test
113 CommAutoTest 1602 000 RP Comm Auto Test
114 DateTimeSet 1625 User 1 - 32;
998(A-Link)
JT User$$$/A-Link Set Clock
115 WalkTestBegin 1607 000
(Installer);
User 1 - 32
-- Walk Test Begin
116 WalkTestEnd 3607 000
(Installer);
User 1 - 32
-- Walk Test End
117 B228 Missing 1333 101 EM ExInput $$ Missing
118 B228 Missing Restore 3333 101 EN ExInput $$ Missing Restore
119 B228 Tamper 1341 101 ES ExInput $$ Tamper
120 B228 Tamper Restore 3341 101 EJ ExInput $$ Tamper Restore
Note: "$" in the string will be replaced by matched number.
86 en | Communication Information Control Panel