Troubleshooting and routine maintenance
C - 37
C
6
Secure the fusing unit with the two lock
levers that are on both sides of the
fusing unit.
7
Move the fusing unit pressure release
levers to the Set position.
8
Close the scanner unit and the back
cover.
9
Turn the machine’s power switch back
on.
Reset the Fusing Unit life counter
1 Press Menu/Set, 7, 4.
2
Press ▲ or ▼ to select Fusing Unit
and press Menu/Set.
The confirmation message appears on
the LCD.
3
Press 1 to reset the life counter.
—OR—
Press 2 to cancel.
CAUTION
Please be careful when replacing the
fusing unit. Do not put pressure on the
fusing unit; it should go in easily. If it does
not, make sure the fusing unit connector is
free to move.
Do not apply force! It could damage both
the fusing unit and the machine.
Fusing Unit
1.Reset 2.Exit