2-83
Confidential
4.7.4 Drum error
4.7.5 Error message prompting drum replacement does not disappear
<User Check>
- Clean the corona wire of the drum unit. 
- Replace the drum unit with a new one.
Step Cause Remedy
1
Dirt on the electrodes of the drum 
unit and those of the machine
Clean the electrodes of the drum unit and 
those of the machine. (Refer to Fig. 2-8 and 
Fig. 2-9.)
2
Dirt on the high-voltage power 
supply PCB terminal
Clean the electrodes of the machine. 
(Refer to Fig. 2-9.)
3
High-voltage power supply PCB 
failure
Replace the high-voltage power supply PCB 
ASSY.
4
Main PCB failure Replace the main PCB ASSY.
<User Check>
- Reset the drum counter according to the manual.
Step Cause Remedy
1
Main PCB failure Replace the main PCB ASSY.