322010 Digital ep set the Functions
Press the # key for about 5 seconds. Input the master
password as per the prompt on the display and press the #
key for confirmation. When you get to the setting status, you
can enter the following settings as per the prompt: (Press on
the 0 key to scroll through the pages).
1. Select 1 and change the master password. The default
master password is 200000. If you want to change it,
you can input your desired password as per the prompt
and press the # key for confirmation. If two inputs are
identical, then the master password is successfully
changed. If not, it will indicate an error and ask you to
re-enter it. Note that only the administrator is entitled to
keep or modify the master password.
2. Select 2 to set the signal types to open/close electric
door locks. As per the interface prompt, we can press the
0 or 1 key to set as either often-closed or often-opened
type.
3. Select 3 to complete the setting of the anti-removal
alarm.
This function must be used together with the anti-removal
alarm pushbutton. By selecting this function and pressing the
anti-removal alarm button the entrance panel automatically
send a removal alarm. If a wrong alarm is sent due to A
wrong settings during installation, switch the power off and
press the alarm button. Then switch the power on again
to cancel the alarm settings. When the entrance panel has
been installed, reopen the anti-removal alarm function.
4. Select 4 to complete the mode setting of the room
number.
Eight options are available for your selections. When using
the entrance panel as the (Riser EP or secondary EP), the first
and the second mode can be selected. When using it as the
(Backbone EP or main EP), the 3rd, 4th 5th, 6th, 7th and 8th
mode can be selected, depending on the actual situations.
The default factory setting is the 1st mode.
Entrance panel functions overview
When used as (Backbone EP or main EP):
Mode 3 and Mode 4: these are commonly used modes.
When the riser number (building number and unit number)
plus floor number plus room number is not above 8 digits,
one of them can be selected. Now the riser number actually
includes the building number. Take Unit 1 of Building 1 for
example, the riser number will be 0101.
Mode 1: 8888
88 Floor number
88 room number
Mode 2: 88A
88 Floor number
A room number
Mode 1: 8888
Mode 2: 88A
RISER MODE
F Fr r
Mode 3: 8888-88 88
Mode 4: 8888-88A
BACKBONE EP OR MAIN EP
Fu u Fr r
Mode 3: 8888-8888
8888 unit number
88 Floor number
88 room number
Mode 4: 8888-88A
8888 unit number
88 Floor number
A room number
Mode 5: 888-88-8888
888 building number
88 unit number
88 Floor number
88 room number
Mode 6: 888-88-88A
888 building number
88 unit number
88 Floor number
A room number
Mode 5 and Mode 6: When the building number plus unit
number (building number and unit number are coded
separately) plus floor number plus room number is not
above 9 digits, one of them can be selected. Take Room
1 5th floor, Unit 2 of Building 101 for example, the riser
number will be 101-02-0501.
Mode 5: 8888-8888
Mode 6: 8888-88A
BACKBONE EP OR MAIN EP
F Fu ub br r