CDE360 Vector Control AC Drive Chapter 6 Parameters Description
When d3.05 is set to 1 (Minimum frequency to running frequency), speed limit mode is shown
by Fig6-D8:
Po s it i ve r un n in g
frequency
Minimum frequency
Speed control is active
t
Speed control is active
Torque control is active
Speed
Figure 6- 27 d3.05=1 Minimum frequency to running frequency
When d3.05 is set to 2 (Negative running frequency to positive running frequency), speed limit
mode is shown by Fig6-D9:
Positive
running
frequency
Negative
running
frequency
Speed control is active
t
Speed control is active
Torque control is active
Speed
Figure 6- 28 d3.05=2 Negative running frequency to positive running frequency
When d3.05 is set to 3 (Running frequency to maximum frequency), speed limit mode is shown
by Fig6-D10:
M a x i m u m
frequency
Negative running
frequency
Speed control is active
t
Speed
Torque control is active
Speed control is active
Figure 6- 29 d3.05=3 Running frequency to maximum frequency