CDE360 Vector Control AC Drive Chapter 6 Parameters Description
This defines the time required for actual torque reference to change from
0 to rated motor torque.
d3.17~d3.18 is the limit of torque reference under torque control
mode,and is also the maximum setting value when AI, FI and
Communication input.
Refer to d3.17 description.
Group d5: Motor 2 Parameters
The AC drive can store two groups of motor parameters. User can switch the desired motor to run
with the related motor parameters. The defines and usage is the same as motor 1. More detail
information, refer to b0, d1,d2.
0: motor 1
Selecting motor 1 as the running motor. Motor 1 related parameters and
control parameters can be set in group b0, d1,d2.
1: motor 2
Selecting motor 2 as the running motor. Motor 2 related parameters and
control parameters can be set in group d5, d6.
If one the input terminal has configured with function 30, motor 1/2
selection is determined by the terminal status regardless setting of d5.00.
0: V/f 1: Open loop vector control 2: Close loop vector control