8400-M117-O1 Rev D
Page 121
11. DIGITAL FILL CONTROL
11.1 Operation
Start
Once all of the settings have been entered for the 201 DFC, the filling
process can be started by pressing the F-Key associated with
“Start/Pause” or by activating the input associated with “Start/Pause”, or
by using the communication port commands (see 11.3 Communication
Port Control section).
Pause
While filling or discharging, the system can be paused by activating the
“Start/Pause” F-Key or input at any time. While paused, the indicator will
disable any active outputs and await restarting or cancelling by the
operator or controlling system.
Resume
While paused, the indicator can resume from where it left off by activating
the “Start/Pause” F-Key or input.
Cancel
While paused, the current batch may be cancelled by activating the
“Discharge” F-Key or input. Please note that this will perform a discharge
cycle before resetting the 201 DFC to the idle state.
Discharge
After filling is complete, if the Auto Dump feature is enabled, the 201 DFC
system should discharge automatically. If Auto Dump is disabled,
activating the “Discharge” F-Key or input will cause a discharge cycle to
occur.