Model 201 Installation & Technical
8400-M117-O1 Rev D
Page 91
5.14 Enable Digital Fill Control
dFC
With dFC displayed, press the F3/ key. The display will change to dFC=.
Proceed to the dFC= (Enable Digital Fill Control) parameter.
dFC= (Select Digital Fill Control Mode)
Press the F3/ key to show the current setting. If the setting displayed is
acceptable, press the F3/ key again to save it. Otherwise, use the
F2/ key to toggle to a new setting and then press the F3/ key to save
it. Allowable settings are:

oFF (Digital Fill Control is off, Disabled)

DIO (Digital Fill Control is Enabled)
Spd= (Select Digital Fill Control Speed)
Press the F3/ key to show the current setting. If the setting displayed is
acceptable, press the F3/ key again to save it. Otherwise, use the
F2/ key to toggle to a new setting and then press the F3/ key to save
it. Allowable settings are:
1sp
Single Speed
2sp
Dual Speed
1spt
Single Speed Timed
2spC
Dual Speed Chatter
typ= (Digital Filling Type)
Press the F3/ key to show the current setting. If the setting displayed is
acceptable, press the F3/ key again to save it. Otherwise, use the
F2/ key to toggle to a new setting and then press the F3/ key to save
it. Allowable settings are:
ac9
Accumulative Gross
acn
Accumulative Net
den
Decumulative Net