Model 201 Installation & Technical
8400-M117-O1 Rev D
Page 85
5.12 Enable Check Weighing
oErUnd
With oErUnd displayed, press the F3/ key. The display will change to
Enabl=. Proceed to the Enabl= (Enable Check Weighing) parameter.
enaBl= (Enable Check Weighing)
Press the F3/ key to show the current setting. If the setting displayed is
acceptable, press the F3/ key again to save it. Otherwise, use the
F2/ key to toggle to a new setting and then press the F3/ key to save
it. Allowable settings are:
no
no (Check Weighing is Disabled)
YES
YES (Check Weighing is Enabled)
NOTE: If oerUnd (Check weighing) is Enabled (YES), the
following prompts, Accept Weight and Over Weight will be active.
ACCPt= (Accept Weight)
Press the F3/ key to show the current setting. If the setting displayed
is acceptable, press the F3/ key again to save it. Otherwise, use the
F2/ and F1/ keys to enter a new setting and then press the F3/ key
to save it. Allowable values for Accept Weight are: 0 through 999,999.
ouEr= (Over Weight)
Press the F3/ key to show the current setting. If the setting displayed
is acceptable, press the F3/ key again to save it. Otherwise, use the
F2/ and F1/ keys to enter a new setting and then press the F3/ key
to save it. Allowable values for Over Weight are: 0 through 999,999.