Model 201 Installation & Technical
8400-M117-O1 Rev D
Page 136
12.4 Operation
Start
Once all of the settings have been entered for the 201 Admix, the
filling process can be started by pressing the F-Key associated
with “Start/Pause” or by activating the input associated with
“Start/Pause”, or by using the communication port commands
(see 12.5 Communication Port Control section).
Pause
While filling or discharging, the system can be paused by activating
the “Start/Pause” F-Key or input at any time. While paused, the
indicator will disable any active outputs and await restarting or
cancelling by the operator or controlling system.
Resume
While paused, the indicator can resume from where it left off by
activating the “Start/Pause” F-Key or input.
Cancel
While paused, the current batch may be cancelled by activating the
“Discharge” F-Key or input. Please note that this will perform a
discharge cycle before resetting the 201 Admix to the idle state.
Discharge
After filling is complete, if the Auto Dump feature is enabled the 201
Admix system should discharge automatically. If Auto Dump is
disabled, activating the “Discharge” F-Key or input will cause a
discharge cycle to occur.