Model 201 Installation & Technical
8400-M117-O1 Rev D
12. 201 ADMIX SYSTEM
12.1 Introduction
This section will describe the added features and configuration of the 201 Admix
system. Included in this reference are the additional setup prompts and their
configuration, as well as a description of the operation of the 201 Admix system.
12.2 Setup and Configuration
The 201 Admix application has the following additional setup prompts and
configuration in addition to the standard 201 setup and configuration. These
configuration parameters can be accessed either through the web configuration,
or using the 201 display through the Digital Fill Control setup group.
dFC
With dFC displayed, press the F3/ key. The display will change to dFC=.
Proceed to the dFC= (Enable Digital Fill Control) parameter.
dFC= (Select Digital Fill Control Mode)
This setting determines the usage of the outputs of the 201 Admix
controller.
Press the F3/ key to show the current setting. If the setting displayed is
acceptable, press the F3/ key again to save it. Otherwise, use the
F2/ key to toggle to a new setting and then press the F3/ key to save
it. Allowable settings are:
oFF (output 1 will be the “At Zero” output and output
2 will be the “Pulse” output)
DIO (output 1 will be the “Fill” output and output 2
will be the “Discharge” output)