Model 201 Installation & Technical
8400-M117-O1 Rev D
5.4 Consecutive Number and Accumulators
With displayed, press the F3/ key. The display will change to CLrAc=.
Proceed to the CLrAc= (Clear Accumulators) parameter.
CLrAc= (Clear Accumulators)
With CLrAC= displayed, press the F3/ key to show the current setting.
If the setting displayed is acceptable, press the F3/ key again to save it.
Otherwise, use the F2/ key to toggle to a new setting and then press the
F3/ key to save it.
Gross and Net accumulators
will be cleared (set to zero)
Gross and Net accumulators
will NOT be cleared
mCn= (Consecutive Number)
With Cn= displayed, press the F3/ key to show the current setting. To
accept the setting displayed, press the F3/ key again to save it.
Otherwise, use the F2/ and F1/ keys to enter a new setting and then
press the F3/ key to save it. Allowable values for consecutive number
are: 0 through 999999.
g acc= (Gross Accumulator)
With g Acc= displayed, press the F3/ key to show the current setting.
To accept the setting displayed, press the F3/ key again to save it.
Otherwise, use the F2/ and F1/ keys to enter a new setting and then
press the F3/ key to save it. Allowable values for the gross accumulator
are: 0 through 999999.
n acc= (Net Accumulator)
With n Acc= displayed, press the F3/ key to show the current setting.
To accept the setting displayed, press the F3/ key again to save it.
Otherwise, use the F2/ and F1/ keys to enter a new setting and then
press the F3/ key to save it. Allowable values for the net accumulator
are: 0 through 999999.