Model 201 Installation & Technical
8400-M117-O1 Rev D
3.9 Power Cable Installation
3.9.1. The POWER CABLE wires are to be connected to the P7 terminal
block on the bottom panel of the weight transmitter. Refer to Figure
No. 2A for an illustration of the connector layout.
3.9.2. Remove the 2-connector terminal block connector from the weight
transmitter. Grasp the terminal block connector and lift straight up
away from the enclosure.
3.9.3. Referring to the table below and the labels on the enclosure for
terminal connections, connect each wire to the terminal block.
3.9.4. Remove 2" of the outer insulation jacket then remove 1/4" of
insulation from each of the wires.
3.9.5. To terminate a wire, loosen the screws in the terminal block and
then insert the wire into the terminal opening. Tighten the screw to
secure the wire in place.
3.9.6. Repeat the procedure until all wires are in place.
P7 - Power Cable Wiring Table