Model 201 Installation & Technical
8400-M117-O1 Rev D
Page 75
5.9 Analog Input/Output
AnAio
With AnAio displayed, press the F3/ key. The display will change to dAC1=.
Proceed to the dAC1= (Analog Output 1, Current) parameter.
dAC1= (Analog Output 1, Current)
Press the F3/ key to show the current setting. If the setting displayed is
acceptable, press the F3/ key again to save it. Otherwise, use the
F2/ key to toggle to a new setting and then press the F3/ key to save
it. Allowable settings are:

Off (Analog Output 1 is disabled)

Track Gross Weight

Track Net Weight

4 mA output

6 mA output

8 mA output

10 mA output

12 mA output

14 mA output

16 mA output

18 mA output

20 mA output
D1A= (Minimum Weight 4 mA)
This is the value, in weight, which outputs 4 mA from the DAC. All
weight below this target will output 4 mA.
Press the F3/ key to show the current setting. To accept the setting
displayed, press the F3/ key again to save it. Otherwise, use the
F2/ and F1/ keys to enter a new setting and then press the F3/ key
to save it. Allowable values are: 0 through 999999.
NOTE: If a negative weight is required for the minimum weight, you
must use the Web Configuration Page.