EasyManua.ls Logo

Cardinal 201 - Analog Input;Output

Cardinal 201
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model 201 Installation & Technical
8400-M117-O1 Rev D
Page 75
5.9 Analog Input/Output
AnAio
With AnAio displayed, press the F3/ key. The display will change to dAC1=.
Proceed to the dAC1= (Analog Output 1, Current) parameter.
dAC1= (Analog Output 1, Current)
Press the F3/ key to show the current setting. If the setting displayed is
acceptable, press the F3/ key again to save it. Otherwise, use the
F2/ key to toggle to a new setting and then press the F3/ key to save
it. Allowable settings are:

Off (Analog Output 1 is disabled)

Track Gross Weight

Track Net Weight

4 mA output

6 mA output

8 mA output

10 mA output

12 mA output

14 mA output

16 mA output

18 mA output

20 mA output
D1A= (Minimum Weight 4 mA)
This is the value, in weight, which outputs 4 mA from the DAC. All
weight below this target will output 4 mA.
Press the F3/ key to show the current setting. To accept the setting
displayed, press the F3/ key again to save it. Otherwise, use the
F2/ and F1/ keys to enter a new setting and then press the F3/ key
to save it. Allowable values are: 0 through 999999.
NOTE: If a negative weight is required for the minimum weight, you
must use the Web Configuration Page.

Table of Contents

Other manuals for Cardinal 201