Model 201 Installation & Technical
8400-M117-O1 Rev D
Page 12
3.5 Load Cell Connections with Over 30 Feet of Cable
For installations with over 30 feet of cable between the weight
transmitter and the load cells, sense wires should be used. The
sense wires must be connected between the +SENS, -SENS
terminals on the weight transmitter and the +EXCITATION, -
EXCITATION wires of the load cells or the +SENS, -SENS
terminals of the load cell trim board or the section seal trim board.