Model 201 Installation & Technical
8400-M117-O1 Rev D
Page 124
Set Fast Target: Sets the fast target weight to fill to
Command Format: <LF>XTARGETFAST=n<CR>
Where:
n = Target weight (0 to capacity)
Response: N/A
Set Slow Target: Sets the slow target weight to fill to
Command Format: <LF>XTARGETSLOW=n<CR>
Where:
n = Target weight (0 to capacity)
Response: N/A
Set Fast Output: Sets the output(s) to use for fast filling
Command Format: <LF>XOUTFAST=n<CR>
Where:
n = 0 15 (see Output Assigning above)
Response: N/A
Set Slow Output: Sets the output(s) to use for slow filling
Command Format: <LF>XOUTSLOW=n<CR>
Where:
n = 0 15 (see Output Assigning above)
Response: N/A
Set Discharge Output: Sets the output(s) to use for discharging
Command Format: <LF>XOUTDISCHARGE=n<CR>
Where:
n = 0 15 (see Output Assigning above)
Response: N/A
Set Trim Value: Sets the current trim value
Command Format: <LF>XTRIM=n<CR>
Where:
n = Trim weight (0 to Target)
Response: N/A

Table of Contents