Set Fill Target: Sets the target weight to fill to
Command Format: <LF>XTARGET=n<CR>
Where:
n = Target weight (0 to capacity)
Response: N/A
Set Trim Value: Sets the current trim value
Command Format: <LF>XTRIM=n<CR>
Where:
n = Trim weight (0 to Target)
Response: N/A
Start/Pause/Resume Filling: Starts/Pauses/Resumes the filling cycle
Command Format: <LF>XSTART<CR>
Response: N/A
Discharge: Starts the discharge cycle
Command Format: <LF>XDISCHARGE<CR>
Response: N/A
Set Pulse Width: Sets the pulse width in milliseconds
Command Format: <LF>XPULSEWIDTH=n<CR>
Where:
n = desired pulse width in milliseconds (1 – 100)
Response: N/A
Set Pulse Target: Sets the change in weight amount to generate a pulse
Command Format: <LF>XPULSETARGET=n<CR>
Where:
n = desired pulse target (0 = off, to capacity)
Response: N/A