8545-M838-O1 Rev D 825 Installation & Technical
118
TROUBLESHOOTING, CONT.
Operation Messages, Cont.
Cannot show net no tare
The “NET” key operation to show gross, tare, and net weights is not permitted when there is
no tare weight.
Cannot print MOTION
Attempt to print ticket while scale is in motion.
Cannot print OVER CAPACITY
Attempt to print ticket while scale is over capacity.
Cannot print BELOW ZERO
Attempt to print ticket while scale is below zero.
Cannot print WEIGHT ERROR
Attempt to print ticket during WEIGHT ERROR condition.
Operator not allowed to change scale
The current operator login does not permit changing the current scale selection.
Operator not allowed tare
The current operator login does not permit using the keypad tare selection.
Operator not allowed push button tare
The current operator login does not permit using the push-button tare selection.
Operator not allowed to set date/time
The current operator login does not permit setting the date/time.
Operator not allowed to chg units
The current operator login does not permit changing the current unit selection.
Operator not allowed to print
The current operator login does not permit using the print function.