EasyManua.ls Logo

Cardinal 825 - External Power Source I;O Connections

Cardinal 825
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8545-M838-O1 Rev D 825 Installation & Technical
21
INSTALLATION, CONT.
I/O (Input/Output) Terminal Connections External Power Source
Refer to the table and Figure No. 17 below to connect each wire to the terminal block.
INPUT/OUTPUT TERMINAL P16 (EXTERNAL POWER SOURCE)
Terminal
Function
Terminal
Function
1
12v (12 to 24VDC)
6
OUT1 (Output 1 @ 100mA MAX.)
2
IN1 (Input 1)
7
OUT2 (Output 2 @ 100mA MAX.)
3
IN2 (Input 2)
8
OUT3 (Output 3 @ 100mA MAX.)
4
IN3 (Input 3)
9
OUT4 (Output 4 @ 100mA MAX.)
5
IN4 (Input 4)
10
GND (Ground)
IMPORTANT!
For completely isolated outputs (when using an external power source), remove J1 and J2.
Connect 12 to 24VDC to P16 pin 1 and GND to P16 pin 10.
Load must still be 100 mA maximum.
Figure No. 17

Table of Contents

Related product manuals