8545-M838-O1 Rev D 825 Installation & Technical
19
INSTALLATION, CONT.
RS485 Terminal Connections
Refer to the table and Figures No. 14 and 15 below to connect each wire to the terminal block.
RS485 COM3 TERMINAL P20
IMPORTANT!
COM3 requires J8 shunt installed on RS485.
2-Wire requires J5 and J6 installed.
4-Wire requires J5 and J6 removed.
Install J9 if 825 is last device on RS-485 bus.
Terminal
Function
1
TXA (Transmit A)
2
TXB (Transmit B)
3
RXA (Receive A)
4
RXB (Receive B)
5
GND (Ground)
Figure No. 14
Figure No. 15